Solis
Solis 1018 (OV-G-I)
AC grid overcurrent detected
Severity
Safe to continue?
No
Technician required?
Recommended
Last verified
September 2026
First safe check
Do not touch AC wiring or the inverter terminals. Note the code, keep the system isolated and contact your installer.
What does 1018 (OV-G-I) mean?
The inverter has detected AC current at the grid connection exceeding safe limits and has disconnected. This is a protective event tied to the AC installation rather than to the solar array.
Which models use this code?
Verified for
- Solis
Not yet verified for: individual model series. This code is recorded at brand level until a document confirms it per family.
Most likely causes
Conditions outside the inverter operating window
Manufacturer documentedThe protective threshold this alarm reports has been exceeded for the AC or DC side of the system.
DC-side or battery-side disturbance
PossibleArray voltage, insulation resistance or battery communication behaviour triggered the alarm.
Measurement or internal hardware deviation
RareIf the alarm returns immediately on a known-good installation, the cause is likely inside the inverter and needs service access.
Safe checks you can perform
- 1
Note the code and the time it appeared
Record the exact alarm text shown on the inverter display or monitoring platform — this is the single most useful detail for your installer.
- 2
Check the visible power path
Confirm the AC breaker for the inverter is on and that the DC isolator is in the position described in your manual. Do not open the enclosure.
- 3
Check the battery indicators if a battery is installed
Note whether the battery and BMS indicators show power and whether the alarm only appears during charge or discharge.
These steps stay outside the enclosure. Never open high-voltage equipment, bypass safety devices or work on live wiring.
When to stop troubleshooting
Stop and contact a qualified technician if the fault returns immediately, the device smells burnt, visible wiring damage exists, the enclosure is hot to the touch, or the manufacturer specifies professional service.
Can a reset clear this fault?
Reset behaviour is not documented for this code. Use only the manufacturer-approved restart sequence described in the device manual, and treat a code that returns immediately as an unresolved fault rather than a reset problem.
Related symptoms
Related fault codes
Sources
Solis Service Center — Alarm and Error Messages
View- Manufacturer
- Solis
- Document version
- —
- Section / page
- Alarm and error message list
- Verified
- September 2026
The inverter has detected AC current at the grid connection exceeding safe limits and has disconnected. This is a protective event tied to the AC installation rather than to the solar array.